Camlock Couplings Working Pressure
SS BR AL PP
Bar Psi Bar Psi Bar Psi Bar Psi
DN15 16 225 16 225 16 225 6 87
DN20 18 250 18 250 16 225 6 87
DN25 18 250 18 250 18 250 6 87
DN32 18 250 18 250 18 250 6 87
SCOPE DN40 18 250 18 250 18 250 6 87
DN50 18 250 18 250 18 250 6 87
This document details the design, materials and dimensions for cam locking couplings
that serve as the link between hoses and connections to transport liquids, solids and DN65 16 225 16 225 16 225 6 87
gases, except liquid gas and s eam. The couplings are capable of operating the pressure
t
range 3 bar to 18 bar working pressure in a working temperature range of − 20 °C up to + DN80 14 220 9 150 9 125 6 87
65 °C. DN100 7 100 7 100 7 100 6 87
WARNING — Line pressure shall be reduced before disconnection. DN125 7 100 5 75 5 75 3 50
DN150 7 100 5 75 5 75 3 50
DN200 5 75 5 75 5 75 3 50