Page 23 - 广州蓝水产品综合样本(ZY170903)
P. 23

'



              02


             ~f:ilff:*
             Level  switch



             ~~.::FMiWiEtlJJHt:l.AD9!Ztf1Drt:l~@...t, M~lt!mtf1mlltfi~fl'.t, ~ffi.fEA:~W3tf11~iJ.Jf'F1§-5, ffi-5~~T:lml:tl'=fit
            i'J!@ffi-5 , OOPiJ.J~'Ffl'.tml:tl~T:l~lHf.
            Installed on suction pipeline or discharge pipeline of canned motor pump, and when liquid flow is broken for
            canned motor pump, level switch will give out protection action signal, and signal type is normally close dry style
            contact signal, normally close contact becomes normally open when protection action takes place.






             03



             B£1J~~H(=;&~E1P)
             Pressure transmitter (  Secondary Containment)



            ~~{:EE~JJl,:ff;Pf;..t, m£€!tJl,~-TIW±.t.Jll!i-T~Wl!l, ~tf14-20mA DC£€!1§-5,  Miffi:&~it!!i,ffifl'.t. ff.t.J~F~~~.
            Installed on motor shell and monitor the pressure of motor stator chamber with output signal of 4-20mADC,
            when shielding can is leaking, pressure will produce sudden change.






             04



            ~EEl 1:9: I"-~fill S!i'.
            l.tm I~ .liD. I-A~ 'IS~
            Temperature monitor



            *fflptlOOP,tf~fl3{~ , :ttEJt..~~iU~~~ , ~~:ij' :
            A  1'l'~iU~lmtl : '!i~.::FMiiilf€!~rt:lAD~~..t , itO.J..t£€!tJl,J\D~iWitl~~imi~~i17ci.1frt:l~~® ;
            B . ~-T~tl3.iU~ii!tl : ~~.::F£€!tJl,~-T~~ • ~ii!tlf€!-tJL..~l3.iU •
            c . ~m7f<~;rou : '!i~-TM~E€!mrt:JFo~~..t . ~ii!UFo~m.iJ(~~;u.
               Adopt ptlOO or thermocouple and furnished with temperature transmitter in option, mainly include:
            A.  Medium temperature monitoring: installed on the suction pipeline of canned motor pump to prevent motor
               1nlet liquid temperature and Max surface temperature from surpassing allowable limit value;
            B  Stator  winding  temperature  monitoring·  installed  in  motor  stator  chamber to  monitor stator  winding
               temperature;
            C .  Bearing  temperature  monitoring:  installed  on R.B.  housing  of canned  motor pump  to monitor medium
               temperature in rear bearing chamber;




                                                                                                              22
                                                                                                           1. ' •\~~UJ
                                                                                                        .\\i. HOR i'L· ~P


                                                                                                                    1
                                                       ...
   18   19   20   21   22   23   24