Page 23 - 广州蓝水产品综合样本(ZY170903)
P. 23
'
02
~f:ilff:*
Level switch
~~.::FMiWiEtlJJHt:l.AD9!Ztf1Drt:l~@...t, M~lt!mtf1mlltfi~fl'.t, ~ffi.fEA:~W3tf11~iJ.Jf'F1§-5, ffi-5~~T:lml:tl'=fit
i'J!@ffi-5 , OOPiJ.J~'Ffl'.tml:tl~T:l~lHf.
Installed on suction pipeline or discharge pipeline of canned motor pump, and when liquid flow is broken for
canned motor pump, level switch will give out protection action signal, and signal type is normally close dry style
contact signal, normally close contact becomes normally open when protection action takes place.
03
B£1J~~H(=;&~E1P)
Pressure transmitter ( Secondary Containment)
~~{:EE~JJl,:ff;Pf;..t, m£€!tJl,~-TIW±.t.Jll!i-T~Wl!l, ~tf14-20mA DC£€!1§-5, Miffi:&~it!!i,ffifl'.t. ff.t.J~F~~~.
Installed on motor shell and monitor the pressure of motor stator chamber with output signal of 4-20mADC,
when shielding can is leaking, pressure will produce sudden change.
04
~EEl 1:9: I"-~fill S!i'.
l.tm I~ .liD. I-A~ 'IS~
Temperature monitor
*fflptlOOP,tf~fl3{~ , :ttEJt..~~iU~~~ , ~~:ij' :
A 1'l'~iU~lmtl : '!i~.::FMiiilf€!~rt:lAD~~..t , itO.J..t£€!tJl,J\D~iWitl~~imi~~i17ci.1frt:l~~® ;
B . ~-T~tl3.iU~ii!tl : ~~.::F£€!tJl,~-T~~ • ~ii!tlf€!-tJL..~l3.iU •
c . ~m7f<~;rou : '!i~-TM~E€!mrt:JFo~~..t . ~ii!UFo~m.iJ(~~;u.
Adopt ptlOO or thermocouple and furnished with temperature transmitter in option, mainly include:
A. Medium temperature monitoring: installed on the suction pipeline of canned motor pump to prevent motor
1nlet liquid temperature and Max surface temperature from surpassing allowable limit value;
B Stator winding temperature monitoring· installed in motor stator chamber to monitor stator winding
temperature;
C . Bearing temperature monitoring: installed on R.B. housing of canned motor pump to monitor medium
temperature in rear bearing chamber;
22
1. ' •\~~UJ
.\\i. HOR i'L· ~P
1
...