Page 32 - 杭州力夫机电--产品画册
P. 32
隔膜增压泵 Diaphragm booster pumps
LFP pump
1000系列 隔膜增压泵
1000 Series diaphragm booster pump
流量曲线 Flow Curve
When the motor drives the outer rotor (that is, the outer magnetic steel) assembly to
rotateThrough the action of the magnetic field, the magnetic field line passes
through the isolation sleeve and drives the innerThe rotor (that is, the inner magnetic
steel) assembly rotates synchronously with the impeller .
1000 1000
LFP 21000J-FD
LFP 11000J-V
接口方式 Interface method
LFP 21000J-V
LFP 21000W-FD
(双头大四腔)
LFP 21000W
(大四腔)
LFP 11000W
(大四腔)
NPT3/8螺纹 (3/8"NPT) NPT3/8双0螺纹 (3/8"NPT"0")
1000A 1000A
LFP 21000J-FD1
LFP 21000J-V1
LFP 11000J-V1
LFP 21000W-FD1
(双头大四腔)
LFP 21000W-A
(大四腔)
LFP 11000W-A
(大四腔)
3分U型内插 3分内插
(3 points U-shaped internal plug) (3 points internal insertion)
产品参数 Product parameters
安装尺寸 Installation size
型号 额定电压 进水压力 工作压力 工作电流 工作流量 开放流量 封堵压力 最大电流
LFP11000J-V ≤4.5A ≥5500ml/min 1.05-1.25Mpa ≤5.8A
24V DC
LFP11000W ≤4.5A ≥6000ml/min 0.95-1.15Mpa ≤5.8A
(大四腔)
≥4500ml/min
LFP21000J-V ≤3.2A 1.05-1.25Mpa ≤4.0A
0.2MPa 0.7MPa ≥5500ml/min
LFP21000J-FD ≤3.2A 1.05-1.2MPa ≤4.0A
36V DC
LFP21000W ≤3.2A / ≤3.5A ≥4500ml/min / 1.05~1.2MPa ≤4.0A / ≤4.5A
(大四腔) ≥5000ml/min
≥6000ml/min
LFP21000W-FD ≤3.2A ≥4500ml/min 1.0-1.2MPa
(双头) ≤4.0A
LFP11000J-V1 ≤5.0A 1.1-1.3Mpa ≤6.0A
24V DC
LFP11000W-A
(大四腔) ≤5.0A 0.95-1.15MPa ≤6.0A
≥6000ml/min
LFP21000J-V1 0.2MPa 0.7MPa ≥5000ml/min 1.1-1.3Mpa
LFP21000J-FD1 36V DC ≤3.5A 1.05-1.2MPa ≤4.5A
(J双头)
LFP21000W-FD1 ≥6500ml/min
(双头泵) 1.0-1.2MPa
03 04